UKAS Accredited Dynamic Tests

Type of test/Properties measured/
Range of measurement

Standard specifications/Equipment/
Techniques used

ENVIRONMENTAL TESTS (non-explosive items)  

DYNAMIC

VIBRATION - Sinusoidal (ambient temperature)
Freq range: 5 to 3000 Hz
Peak thrust: 13.3 kN
Max pk/pk displacement: +/- 12.5 mm

VIBRATION - Random, Sine on Random, Simulated Gunfire (ambient temperature)
Freq range: 5 to 3000 Hz
RMS: 13.3 kN
Max pk/pk displacement: +/- 12.5 mm

 

BS EN 60068-2-6:1996
BS 2011:Fe:1983(1986)
BS 2011:Fd:1973(1984)
IEC 68-2-6:1982
IEC 68-2-34:1973
DEF STAN 07-55:1975
Tests A1, A2
MIL-STD-810E: 1989(1990)
Methods 514.4, 519.4

SHOCK - Half sine, Trapezoidal, Sawtooth (ambient temperature)
Max severity: 600 gn
Pulse width: 1 to 80 ms
Max item mass: 230 kg
Max item size: 0.6 m x 0.6 m x 0.6 m

BS EN 60068-2-27:1993
BS 2011:Ea:1988
IEC 68-2-27:1987
DEF STAN 07-55:1975
Test A3
MIL-STD-810E: 1989(1990)
Method 516.4

SYNTHESISED SHOCK PULSE
Max severity: 50 g

NES 1004, 1981, Data Sheet 27

BUMP
(ambient temperature)
Max item mass: 50 kg
Table size: 0.9 m x 0.6 m x 1.5 m (high)
Max severities: 40 gn for 6 ms

BS 2011:Eb:1987
IEC 68-2-29-1987
DEF STAN 07-55:1975
Test A5
DROP and TOPPLE
(ambient temperature)
Max item mass: 100 kg
Max item size: 1.0 m x 1.0 m x 1.0 m
BS 2011:Ec:1977(1983)
BS EN 60068-2-31:1993
IEC 68-2-31-1969
DEF STAN 07-55:1975
Test A4
FREE FALL - vertical impact
(ambient temperature)
Max item mass: 100 kg
Max item size: 1.0 m x 1.0 m x 1.0 m (concrete)
Max suspension height: 1.5 m
BS 2011:Ed:1977
BS EN 60068-2-32:1993
IEC 68-2-32-1975

DYNAMIC
Combined Parameters

VIBRATION - sinusoidal
Freq range: 5 to 3000 Hz
Peak thrust: 13.3 kN
Max pk/pk displacement: 25.4 mm
Temp range: -40°C to +125°C
Max rate of change: 10°C/min
Chamber size: 0.7 m x 0.7 m x 0.7 m

 

BS 2011:Fe:1983
IEC 68-2-6-1982
DEF STAN 07-55:1975
Test A1
MIL STD 810E:1989
Method 514.4

VIBRATION - random
Freq range: 5 to 3000 Hz
RMS thrust: 9.1 kN
Max pk/pk displacement: 25.4 mm
Temp range: -40°C to +125°C
Max rate of change: 10°C/min
Chamber size: 0.7 m x 0.7 m x 0.7 m

BS 2011:Fd:1973(1984)
IEC 68-2-34-1973
DEF STAN 07-55:1975
Test A2
MIL STD 810E:1989
Method 514.4

SHOCK
Half Sine, Trapezoidal Terminal Peak, Sawtooth
Max severity: 120 g
Max peak thrust: 20 kN
Max pk/pk displacement: 25.4 mm
Max velocity: 1.2 m/s
Max item mass: 160 kg
Temp range: -40°C to +125°C
Max chamber size: 0.7 m x 0.7 m x 0.7 m

BS 2011:Ea:1988
BS EN 60068-2-27:1993
IEC 68-2-27:1987
DEF STAN 07-55:1975
Test A3
MIL-STD-810E: 1989
Method 516.4
BUMP
Max severity: 120 g
Max peak thrust: 20 kN
Max pk/pk displacement: 25.4 mm
Max velocity: 1.2 m/s
Max item mass: 160 kg
Temp range: -40°C to +125°C
Max chamber size: 0.7 m x 0.7 m x 0.7 m
BS 2011:Eb:1987
IEC 68-2-29:1987
DEF STAN 07-55:1975
Test A5